This page was exported from Top Exam Collection [ http://blog.topexamcollection.com ] Export date:Sun Feb 23 20:46:00 2025 / +0000 GMT ___________________________________________________ Title: The Ultimate Huawei H12-425_V2.0 Dumps PDF Review [Q43-Q59] --------------------------------------------------- The Ultimate Huawei H12-425_V2.0 Dumps PDF Review Achieve The Utmost Performance In H12-425_V2.0 Exam Pass Guaranteed Q43. Which of the following fan control modes are supported by NetCo18000-C series room-level chilled water intelligent cooling products? (Multiple choice)  Return air control  Pressure Control  Mixed air control  Differential pressure control  Supply air control Q44. If the UPS5000-400K cuts the bypass and closes the maintenance side station, both the main power module and the bypass module stop working.  TRUE  FALSE Q45. The form of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( ). (Fill in the blank)  Wet film Q46. When the UPS is in parallel, the input phase sequence of the main bypass of each UPS needs to be checked, and the output phase sequence of a single pair is not required.  TRUE  FALSE Q47. In the naming of UPS5000-E-120K-HASBS, the meaning of the letter E is ().  208V voltage body  E-Series Modular UPS  Input switch type is ATS  Input switch type is MCCB Q48. Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack is 1+1 redundant, the single-machine backup power scheme is adopted, the backup power scheme for each machine, 3 sets of batteries per rack, 40 cells per set, the capacity of the main switch box is:  630A  500A  250A  320A Q49. The domestic power supply system is 380v/50Hz.  True  False Q50. What kind of incoming and outgoing lines can be realized by the FusionModule2000 integrated power distribution cabinet?  Under the line and under the line  Up in and out on the line  Top-in and bottom-out lines  Down in and out on the line Q51. UPS5000-E (50kVA power module) single rack can accommodate up to 300kVA.  True  False Q52. Which of the following functions can be achieved by modular UPS? (Multiple choice)  Online hot-swappable  Can be expanded online  Single machine can realize N+X redundant configuration  Unit price can achieve 2N redundant configuration Q53. NETECO’s report functions are displayed in various forms, with a variety of visual presentations such as bar charts, pie charts, and curve charts.  TRUE  FALSE Q54. Users can monitor the status of equipment such as UPS and air conditioners on the ECC800.  True  False Q55. The () air supply method is suitable for data centers with high power density of a single cabinet.  Upper air supply  Under the floor  Upper air duct  Row level Q56. Which of the following humidification forms has the lowest energy consumption?  Wet film humidification  Electrode humidification  Infrared humidification Q57. How many KG is the static load of the FusionModule2000 cabinet?  2400  1800  1500  2000 Q58. What are the possible reason of the excessive noise of the NETCOL5000-C fan? (Multiple choice)  The filter is dirty and blocked  The air outlet of the fan is dirty and blocked  Loose fan installation  Fan failure Q59. What is the possible cause of the high discharge temperature of the NETCOL5000-A air conditioner compressor? (Multiple choice)  Refrigerant circuit or device blockage  The installation position of the outdoor unit is wrong  The condenser is dirty and blocked, resulting in poor heat dissipation  Too little refrigerant charge  Loading … Achive your Success with Latest Huawei H12-425_V2.0 Exam: https://www.topexamcollection.com/H12-425_V2.0-vce-collection.html --------------------------------------------------- Images: https://blog.topexamcollection.com/wp-content/plugins/watu/loading.gif https://blog.topexamcollection.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-04-23 13:03:26 Post date GMT: 2023-04-23 13:03:26 Post modified date: 2023-04-23 13:03:26 Post modified date GMT: 2023-04-23 13:03:26