This page was exported from Top Exam Collection [ http://blog.topexamcollection.com ] Export date:Tue Jan 21 7:34:56 2025 / +0000 GMT ___________________________________________________ Title: [Full-Version] 2023 Updated EMC Study Guide DES-4122 Dumps Questions [Q14-Q35] --------------------------------------------------- [Full-Version] 2023 Updated EMC Study Guide DES-4122 Dumps Questions Newest DES-4122 Exam Dumps Achieve Success in Actual DES-4122 Exam EMC DES-4122 Exam is an essential certification for professionals who want to advance their careers in the field of server administration. Specialist - Implementation Engineer, PowerEdge Exam certification validates the candidate's expertise in implementing and managing PowerEdge servers, which are widely used in enterprise-level organizations. Specialist - Implementation Engineer, PowerEdge Exam certification opens up new career opportunities for professionals and helps them to enhance their skills and knowledge in server administration. Specialist - Implementation Engineer, PowerEdge Exam certification is also a prerequisite for other advanced Dell EMC certifications, such as the Specialist - Implementation Engineer, VxRail Appliance Exam.   Q14. What is required for iDRAC Direct 2.0 to connect with IDRAC9 interfaces such as RACADM and WSMAN?  Wi-Fi connection  NFC connection  Ethernet cable  Micro-AB USB Q15. A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?Note: It is necessary to dose (x) the simulator window before you can select a response to this question.  The Virtual Console is disabled  Operating system not installed on remote server  The server has been powered down  There are more than the maximum number of active sessions Q16. A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?  iDRAC Datacenter license is installed.  Ethernet port LOM1 is cabled and the link light is green.  iDRAC dedicated NIC port is cabled and the link light is green  iDRAC Enterprise license is installed Q17. An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.What task should be completed to troubleshoot this issue?  Confirm the System Input Power CAP is not set to Low  Set the PSU AC redundancy to 1+1  Set the PSU AC redundancy to 1+0  Verify the new PSU is the same type and wattage rating Q18. How can a technician know whether IDRAC9 System Lockdown mode is enabled?  Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots  Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots  Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots  Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots Q19. You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.  Send us your suggestion for this simulation task.  A technician wants to Q20. Where is the data stored to allow Easy Restore to successfully complete a system board replacement?  NAND Flash module on the disk drive mid plane  IDSDM SD card  vFlash SD card  Serial Flash storage in the server’s front panel Q21. A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned How should the technician obtain access to the remaining 2 TB (approximately) of storage?  Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server  Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB  Upgrade to a newer version of the operating system  Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again Q22. What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?  Ensures that the installed operating system is authentic  Ensures that the server has a valid Service Tag number  Ensures that no unauthorized BIOS or firmware codes are run  Ensures that the server boots only when connected to a verified network Q23. How can the ePSA be accessed?  iDRAC  Lifecycle Controller  VMware vSphere plug-in  OMSA Q24. A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.How can the technician find out what the error message was?  Access the Lifecycle Controller and view the last boot cycle video capture entry  Reload the BIOS firmware  Export the Server profile and analyze for any POST errors  Access the iDRAC and view the last boot cycle video capture entry Q25. A technician working with a Dell EMC PowerEdge 1 take corrective action?  Check the System Event LogCheck PSU LEDReseat the PSU  Check the System Event LogCheck PSU LEDDo a virtual reseat of the iDRAC  Check the LCC LogCheck PSU LEDReseat the CPU  Check the LCC LogCheck PSU LEDReseat the PSU Q26. A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.How can the technician find out what the error message was?  Access the Lifecycle Controller and view the last boot cycle video capture entry  Reload the BIOS firmware  Export the Server profile and analyze for any POST errors  Access the iDRAC and view the last boot cycle video capture entry Q27. For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.When you have finished using the simulator, click Next.  Send us your suggestion for this simulation task.  A technician wants to Q28. A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only “sees” 24 threads in total.Which setting should the technician change in Processor Settings in the System BIOS?  System Profile  Virtualization Technology  HyperThreading  Number of Cores per Processor Q29. Which processor configuration is used by the Dell EMC PowerEdge R740 server?  4 socket AMD  2 socket AMD  2 socket Intel  4 socket Intel Q30. You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?  RAID 0  RAID 5  RAID 1  Non-RAID Mirroring Q31. An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?  Hot-plug power supply, 750 W – qty 1  Hot-plug power supply, 1100W – qty 1  Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters – qty 2  C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord – qty 2 Q32. Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition. Q33. What happened on April 30, 2019?Note: It is necessary to dose (x) the simulator window before you can select a response to this question.  Option A  Option B  Option C  Option D Q34. A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.What action should a technician take to help accomplish this goal?  Configure servers to access the remote firmware repository  Enable the Match Firmware of Replaced Part setting in the system BIOS  Install and configure a repository manager  Enable the Collect System Inventory On Restart (CSIOR) attribute Q35. You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?  RAID 0  RAID 5  RAID 1  Non-RAID Mirroring  Loading … EMC DES-4122 (Specialist - Implementation Engineer, PowerEdge) Certification Exam is a globally recognized certification program designed to validate the skills and knowledge of professionals who are responsible for implementing and managing PowerEdge servers. Specialist - Implementation Engineer, PowerEdge Exam certification program is an ideal choice for IT professionals who are looking to validate their skills and knowledge in PowerEdge server implementation, configuration, and management.   Updated EMC DES-4122 Dumps – Check Free DES-4122 Exam Dumps: https://www.topexamcollection.com/DES-4122-vce-collection.html --------------------------------------------------- Images: https://blog.topexamcollection.com/wp-content/plugins/watu/loading.gif https://blog.topexamcollection.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-10-12 14:15:50 Post date GMT: 2023-10-12 14:15:50 Post modified date: 2023-10-12 14:15:50 Post modified date GMT: 2023-10-12 14:15:50