[Full-Version] 2023 Updated EMC Study Guide DES-4122 Dumps Questions [Q14-Q35]

October 12, 2023 0 Comments

Rate this post

[Full-Version] 2023 Updated EMC Study Guide DES-4122 Dumps Questions

Newest DES-4122 Exam Dumps Achieve Success in Actual DES-4122 Exam

EMC DES-4122 Exam is an essential certification for professionals who want to advance their careers in the field of server administration. Specialist – Implementation Engineer, PowerEdge Exam certification validates the candidate’s expertise in implementing and managing PowerEdge servers, which are widely used in enterprise-level organizations. Specialist – Implementation Engineer, PowerEdge Exam certification opens up new career opportunities for professionals and helps them to enhance their skills and knowledge in server administration. Specialist – Implementation Engineer, PowerEdge Exam certification is also a prerequisite for other advanced Dell EMC certifications, such as the Specialist – Implementation Engineer, VxRail Appliance Exam.

 

Q14. What is required for iDRAC Direct 2.0 to connect with IDRAC9 interfaces such as RACADM and WSMAN?

 
 
 
 

Q15. A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

 
 
 
 

Q16. A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?

 
 
 
 

Q17. An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?

 
 
 
 

Q18. How can a technician know whether IDRAC9 System Lockdown mode is enabled?

 
 
 
 

Q19. You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

 
 

Q20. Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

 
 
 
 

Q21. A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned How should the technician obtain access to the remaining 2 TB (approximately) of storage?

 
 
 
 

Q22. What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

 
 
 
 

Q23. How can the ePSA be accessed?

 
 
 
 

Q24. A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

 
 
 
 

Q25. A technician working with a Dell EMC PowerEdge 1 take corrective action?

 
 
 
 

Q26. A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

 
 
 
 

Q27. For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.
When you have finished using the simulator, click Next.

 
 

Q28. A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only “sees” 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

 
 
 
 

Q29. Which processor configuration is used by the Dell EMC PowerEdge R740 server?

 
 
 
 

Q30. You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?

 
 
 
 

Q31. An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?

 
 
 
 

Q32. Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.

Q33. What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

 
 
 
 

Q34. A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?

 
 
 
 

Q35. You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?

 
 
 
 

EMC DES-4122 (Specialist – Implementation Engineer, PowerEdge) Certification Exam is a globally recognized certification program designed to validate the skills and knowledge of professionals who are responsible for implementing and managing PowerEdge servers. Specialist – Implementation Engineer, PowerEdge Exam certification program is an ideal choice for IT professionals who are looking to validate their skills and knowledge in PowerEdge server implementation, configuration, and management.

 

Updated EMC DES-4122 Dumps – Check Free DES-4122 Exam Dumps: https://www.topexamcollection.com/DES-4122-vce-collection.html

Leave a Reply

Your email address will not be published. Required fields are marked *

Enter the text from the image below